8 research outputs found

    Spatial variation in automated burst suppression detection in pharmacologically induced coma

    Get PDF
    Burst suppression is actively studied as a control signal to guide anesthetic dosing in patients undergoing medically induced coma. The ability to automatically identify periods of EEG suppression and compactly summarize the depth of coma using the burst suppression probability (BSP) is crucial to effective and safe monitoring and control of medical coma. Current literature however does not explicitly account for the potential variation in burst suppression parameters across different scalp locations. In this study we analyzed standard 19-channel EEG recordings from 8 patients with refractory status epilepticus who underwent pharmacologically induced burst suppression as medical treatment for refractory seizures. We found that although burst suppression is generally considered a global phenomenon, BSP obtained using a previously validated algorithm varies systematically across different channels. A global representation of information from individual channels is proposed that takes into account the burst suppression characteristics recorded at multiple electrodes. BSP computed from this representative burst suppression pattern may be more resilient to noise and a better representation of the brain state of patients. Multichannel data integration may enhance the reliability of estimates of the depth of medical coma.National Institutes of Health (U.S.) (Grant K23 NS090900)National Institute of Neurological Diseases and Stroke (U.S.) (Grant K23 NS090900)National Institutes of Health (U.S.) (Grant DP2-OD006454)National Institutes of Health (U.S.) (Grant TROI-GMI04948

    Automation of Classical QEEG trending methods for early detection of delayed cerebral ischemia: More work to do

    No full text
    The purpose of this study is to evaluate automated implementations of continuous EEG monitoring-based detection of delayed cerebral ischemia based on methods used in classical retrospective studies. We studied 95 patients with either Fisher 3 or Hunt Hess 4 to 5 aneurysmal subarachnoid hemorrhage who were admitted to the Neurosciences ICU and underwent continuous EEG monitoring. We implemented several variations of two classical algorithms for automated detection of delayed cerebral ischemia based on decreases in alpha-delta ratio and relative alpha variability. Of 95 patients, 43 (45%) developed delayed cerebral ischemia. Our automated implementation of the classical alpha-delta ratio-based trending method resulted in a sensitivity and specificity (Se,Sp) of (80,27)%, compared with the values of (100,76)% reported in the classic study using similar methods in a nonautomated fashion. Our automated implementation of the classical relative alpha variability-based trending method yielded (Se,Sp) values of (65,43)%, compared with (100,46)% reported in the classic study using nonautomated analysis. Our findings suggest that improved methods to detect decreases in alpha-delta ratio and relative alpha variability are needed before an automated EEG-based early delayed cerebral ischemia detection system is ready for clinical use.SCOPUS: re.jinfo:eu-repo/semantics/publishe

    Quantitative Electroencephalogram Trends Predict Recovery in Hypoxic-Ischemic Encephalopathy

    No full text
    OBJECTIVES: Electroencephalogram features predict neurologic recovery following cardiac arrest. Recent work has shown that prognostic implications of some key electroencephalogram features change over time. We explore whether time dependence exists for an expanded selection of quantitative electroencephalogram features and whether accounting for this time dependence enables better prognostic predictions. DESIGN: Retrospective. SETTING: ICUs at four academic medical centers in the United States. PATIENTS: Comatose patients with acute hypoxic-ischemic encephalopathy.None. MEASUREMENTS AND MAIN RESULTS: We analyzed 12,397 hours of electroencephalogram from 438 subjects. From the electroencephalogram, we extracted 52 features that quantify signal complexity, category, and connectivity. We modeled associations between dichotomized neurologic outcome (good vs poor) and quantitative electroencephalogram features in 12-hour intervals using sequential logistic regression with Elastic Net regularization. We compared a predictive model using time-varying features to a model using time-invariant features and to models based on two prior published approaches. Models were evaluated for their ability to predict binary outcomes using area under the receiver operator curve, model calibration (how closely the predicted probability of good outcomes matches the observed proportion of good outcomes), and sensitivity at several common specificity thresholds of interest. A model using time-dependent features outperformed (area under the receiver operator curve, 0.83 ± 0.08) one trained with time-invariant features (0.79 ± 0.07; p \u3c 0.05) and a random forest approach (0.74 ± 0.13; p \u3c 0.05). The time-sensitive model was also the best-calibrated. CONCLUSIONS: The statistical association between quantitative electroencephalogram features and neurologic outcome changed over time, and accounting for these changes improved prognostication performance

    Quantitative Electroencephalogram Trends Predict Recovery in Hypoxic-Ischemic Encephalopathy*

    No full text
    OBJECTIVES: Electroencephalogram features predict neurologic recovery following cardiac arrest. Recent work has shown that prognostic implications of some key electroencephalogram features change over time. We explore whether time dependence exists for an expanded selection of quantitative electroencephalogram features and whether accounting for this time dependence enables better prognostic predictions. DESIGN: Retrospective. SETTING: ICUs at four academic medical centers in the United States. PATIENTS: Comatose patients with acute hypoxic-ischemic encephalopathy.None. MEASUREMENTS AND MAIN RESULTS: We analyzed 12,397 hours of electroencephalogram from 438 subjects. From the electroencephalogram, we extracted 52 features that quantify signal complexity, category, and connectivity. We modeled associations between dichotomized neurologic outcome (good vs poor) and quantitative electroencephalogram features in 12-hour intervals using sequential logistic regression with Elastic Net regularization. We compared a predictive model using time-varying features to a model using time-invariant features and to models based on two prior published approaches. Models were evaluated for their ability to predict binary outcomes using area under the receiver operator curve, model calibration (how closely the predicted probability of good outcomes matches the observed proportion of good outcomes), and sensitivity at several common specificity thresholds of interest. A model using time-dependent features outperformed (area under the receiver operator curve, 0.83 ± 0.08) one trained with time-invariant features (0.79 ± 0.07; p < 0.05) and a random forest approach (0.74 ± 0.13; p < 0.05). The time-sensitive model was also the best-calibrated. CONCLUSIONS: The statistical association between quantitative electroencephalogram features and neurologic outcome changed over time, and accounting for these changes improved prognostication performance

    Quantitative Electroencephalogram Trends Predict Recovery in Hypoxic-Ischemic Encephalopathy

    No full text
    OBJECTIVES: Electroencephalogram features predict neurologic recovery following cardiac arrest. Recent work has shown that prognostic implications of some key electroencephalogram features change over time. We explore whether time dependence exists for an expanded selection of quantitative electroencephalogram features and whether accounting for this time dependence enables better prognostic predictions. DESIGN: Retrospective. SETTING: ICUs at four academic medical centers in the United States. PATIENTS: Comatose patients with acute hypoxic-ischemic encephalopathy.None. MEASUREMENTS AND MAIN RESULTS: We analyzed 12,397 hours of electroencephalogram from 438 subjects. From the electroencephalogram, we extracted 52 features that quantify signal complexity, category, and connectivity. We modeled associations between dichotomized neurologic outcome (good vs poor) and quantitative electroencephalogram features in 12-hour intervals using sequential logistic regression with Elastic Net regularization. We compared a predictive model using time-varying features to a model using time-invariant features and to models based on two prior published approaches. Models were evaluated for their ability to predict binary outcomes using area under the receiver operator curve, model calibration (how closely the predicted probability of good outcomes matches the observed proportion of good outcomes), and sensitivity at several common specificity thresholds of interest. A model using time-dependent features outperformed (area under the receiver operator curve, 0.83 ± 0.08) one trained with time-invariant features (0.79 ± 0.07; p < 0.05) and a random forest approach (0.74 ± 0.13; p < 0.05). The time-sensitive model was also the best-calibrated. CONCLUSIONS: The statistical association between quantitative electroencephalogram features and neurologic outcome changed over time, and accounting for these changes improved prognostication performance.SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    Burst Suppression: Causes and Effects on Mortality in Critical Illness

    No full text
    BACKGROUND: Burst suppression in mechanically ventilated intensive care unit (ICU) patients is associated with increased mortality. However, the relative contributions of propofol use and critical illness itself to burst suppression; of burst suppression, propofol, and critical illness to mortality; and whether preventing burst suppression might reduce mortality, have not been quantified. METHODS: The dataset contains 471 adults from seven ICUs, after excluding anoxic encephalopathy due to cardiac arrest or intentional burst suppression for therapeutic reasons. We used multiple prediction and causal inference methods to estimate the effects connecting burst suppression, propofol, critical illness, and in-hospital mortality in an observational retrospective study. We also estimated the effects mediated by burst suppression. Sensitivity analysis was used to assess for unmeasured confounding. RESULTS: The expected outcomes in a counterfactual randomized controlled trial (cRCT) that assigned patients to mild versus severe illness are expected to show a difference in burst suppression burden of 39%, 95% CI [8-66]%, and in mortality of 35% [29-41]%. Assigning patients to maximal (100%) burst suppression burden is expected to increase mortality by 12% [7-17]% compared to 0% burden. Burst suppression mediates 10% [2-21]% of the effect of critical illness on mortality. A high cumulative propofol dose (1316 mg/kg) is expected to increase burst suppression burden by 6% [0.8-12]% compared to a low dose (284 mg/kg). Propofol exposure has no significant direct effect on mortality; its effect is entirely mediated through burst suppression. CONCLUSIONS: Our analysis clarifies how important factors contribute to mortality in ICU patients. Burst suppression appears to contribute to mortality but is primarily an effect of critical illness rather than iatrogenic use of propofol

    Automated Annotation of Epileptiform Burden and Its Association with Outcomes

    No full text
    OBJECTIVE: This study was undertaken to determine the dose-response relation between epileptiform activity burden and outcomes in acutely ill patients. METHODS: A single center retrospective analysis was made of 1,967 neurologic, medical, and surgical patients who underwent \u3e16 hours of continuous electroencephalography (EEG) between 2011 and 2017. We developed an artificial intelligence algorithm to annotate 11.02 terabytes of EEG and quantify epileptiform activity burden within 72 hours of recording. We evaluated burden (1) in the first 24 hours of recording, (2) in the 12-hours epoch with highest burden (peak burden), and (3) cumulatively through the first 72 hours of monitoring. Machine learning was applied to estimate the effect of epileptiform burden on outcome. Outcome measure was discharge modified Rankin Scale, dichotomized as good (0-4) versus poor (5-6). RESULTS: Peak epileptiform burden was independently associated with poor outcomes (p \u3c 0.0001). Other independent associations included age, Acute Physiology and Chronic Health Evaluation II score, seizure on presentation, and diagnosis of hypoxic-ischemic encephalopathy. Model calibration error was calculated across 3 strata based on the time interval between last EEG measurement (up to 72 hours of monitoring) and discharge: (1) 10 days between last measurement and discharge, 0.0998 (95% CI = 0.0698-0.1335). After adjusting for covariates, increase in peak epileptiform activity burden from 0 to 100% increased the probability of poor outcome by 35%. INTERPRETATION: Automated measurement of peak epileptiform activity burden affords a convenient, consistent, and quantifiable target for future multicenter randomized trials investigating whether suppressing epileptiform activity improves outcomes
    corecore